Long
|
|
|
|
|
Long Hand Drivers |
|
|
LHD-B |
Two piece type |
|
body |
(separated) tips |
LHD-B |
|
|
|
DT-S |
|
DT-L |
|
|
LHD-OB-S |
One piece type |
|
body |
(fixed) tip |
LHD-B |
DT-S |
|
|
LHD-OB-L |
One piece type |
|
body |
(fixed) tip |
LHD-B |
DT-L |
|
|
Two piece type : The tip and the body of this driver are separated
One piece type : The tip and the body of this driver are not separated
You may use the 'DT-S' or 'DT-L' according to the type of the microimplant.
You can order the driver-tip (or driver body) separately. |
|
Torque
|
|
|
|
Torque Guided Driver |
|
|
LHD-B-TG |
|
|
|
|
|
|
Torque resisting force of AbosoAnchor® microimplants. |
|
The TG-Driver is designed to prevent breakage(fracture) of microimplant during driving by adjusting torque gauge which
is built in hand driver.
The amount of registing torque force ranged from 0.5 Kgf.Cm to 2.0 Kgf.Cm can be indicated by the edge of Rotating
Handle on the numeric Scale.
Initially the edge of Rotating Handle indicates about 0.5 Scale, and it's resisting torque force is about 0.5 Kgf.Cm
The edge of Rotating Handle can be moved back & forth on the Scale by rotating the Locking Nut.
When we want to adjust torque resisting force, first release the Supporting Handle by turning into counter-
clockwise direction.
After releasing the Locking Nut, we can move Rotating Handle back & forth by turning the Locking Nut.
After determining the proper scale depending on the items, we have to lock the Locking Nut tightly again. To lock the
Locking Nut, first rotate Supporting Handle in clockwise direction.>
When we exceed determined torque force, we can hear clicking sound of the clutches due to the slippage of them. |
|
Contraangle
|
|
|
Hand Contraangle Driver |
|
|
HCD |
|
|
|
|
|
|
|
Hand Contraangle Driver(HCD) is designed to place Absoanchor microimplant using hands without low speed motor.
Any kind of common (1:1) low speed contraangle handpiece(CH) can be attached to the HCD. Various size of Engine
Driver(ED) should be inserted into the contraangle handpiece.
HCD with contraangle handpiece is easy to access on the limited sites which are difficult to access with straight long
and short hand driver.
For examples, retromolar area, tuberosity, palate, maxillary and mandibular buccal posterior area are easy to access
for removal as well as driving.
If we use Hand Contraangle Driver, the operator can feel the resistance easily during driving & removal of
microimplant compare to electric motor driving. |
|
Short
|
|
|
|
|
|
Short Hand Drivers |
|
|
SHD-S |
|
|
SHD-L |
|
|
|
use
SH, NH, LH, CH
GH 12 Series, GH 13 Series
GH 14 Series, GH 15 Series
GH 16 Series |
|
use
FH, BH, HH, DH, JH
GH 17 Series, GH 18 Series
GH 20 Series, SH 20 Series |
|
|
|
|
|
|
Engine
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engine Drivers |
|
|
|
|
ED17-S |
|
ED19-S |
|
ED26-S |
|
ED36-S |
|
ED17-L |
|
ED19-L |
|
ED26-L |
|
ED36-L |
|
|
use
SH, NH, LH, CH
GH 12 Series, GH 13 Series, GH 14 Series, GH 15 Series
GH 16 Series |
|
use
FH, BH, HH, DH, JH
GH 17 Series, GH 18 Series, GH 20 Series, SH 20 Series |
|
Tips
|
|
|
|
|
|
Driver Tips |
|
|
DT-S |
|
|
|
|
|
|
|
use
SH, NH, LH, CH
GH 12 Series, GH 13 Series
GH 14 Series, GH 15 Series
GH 16 Series |
|
|
DT-L |
|
|
|
|
|
|
|
use
FH, BH, HH, DH, JH
GH 17 Series, GH 18 Series
GH 20 Series, SH 20 Series |
|
Micro dual ball grip system. |
|
|
|